Adjustment of detection range and sensitivity of malleable steel pipe fittings and steel castings

Feb 20, 2023

 

1. Range adjustment
Adjust the detection range on the display screen of the detection instrument, use a straight probe or an angled probe, and select the following test blocks:
①The test block specified in GB/T19799.1-2015 "Nondestructive Testing Ultrasonic Testing No. 1 Calibration Test Block" or GB/T 19799.2-2012 "Nondestructive Testing Ultrasonic Testing No. 2 Calibration Test Block".
② A comparative test block with the same acoustic characteristics as the tested material.
③Use a straight probe to adjust on the body of a steel casting with parallel surfaces and measurable thickness.
Among them, ② and ③ have better accuracy in defect location.

 

2. Sensitivity adjustment
To adjust the sensitivity, use one of the following two methods:
(1) Distance and amplitude correction curve method (DAC method) The distance and amplitude correction curve is obtained by using the echo heights of a series of the same reflector (flat-bottomed hole FBH or horizontal hole SDH), and each reflector has a different sound path.
(2) Distance gain size method (DGS method) The distance gain size method is a curve obtained by using a series of theoretically calculated relationships between the sound path, instrument gain, and the diameter of the flat-bottomed hole perpendicular to the axis of the sound beam.
When using calibration blocks, a transmission correction is required. The transmission correction should not only consider the roughness of the coupling surface, but also the roughness of the bottom surface, because the bottom surface roughness affects the height of the bottom wave. If the bottom surface is a machined surface or the surface roughness Ra≤25μm, the measurement of transmission correction is satisfied.